IICRC S500-based equipment sizing + daily drying log for water-damage restoration pros.
Works fully offline — one file, no account, data stays on your device.
Job intake
Planning aid only. Sizing defaults are editable industry rules-of-thumb
(see Settings for sources). Always verify against your IICRC S500 edition and adjust from daily
psychrometric readings. Mold can begin within 24–48 hours in wet conditions — respond promptly.
Affected rooms
Dimensions in feet. Affected ft² = wet floor area
(defaults to full floor — edit it down for partial rooms).
Room
Dimensions (ft)
Affected ft²
Volume (cu ft)
Carpet
Wet walls
Equipment sizing plan
Room
Air movers
Dehu share (AHAM pints/day)
Notes
Air movers: one base unit per affected room + one per affected square feet ÷ class ratio
(Class 2 default 60, inside the 50–70 range). Dehumidifiers: affected cubic feet × pints-per-cu-ft baseline
× class multiplier → total AHAM pints/day, then ÷ your dehu capacity to get unit count.
Defaults are editable in Settings. Verify on site — the S500 requires adjusting initial equipment
from subsequent days' psychrometric readings.
Daily drying log
Log psychrometric + moisture readings per room per visit. The S500 requires the initial
dehumidification plan to be adjusted from subsequent days' psychrometric readings —
this log is that record. Balanced drying: keep dehumidification rate ≥ evaporation rate.
Date
Room
Temp
RH
Surface MC
Dry std
Progress
Equipment
Notes
Settings & sizing ratios
Air-mover ratio: affected sq ft per mover (base 1 per room + affected ÷ ratio)
Dehumidifier class multiplier (× baseline pints)
Ratio sources (documented): Air movers — S500-derived industry rule-of-thumb:
install one air mover in each affected room, then add one per 50–70 sq ft of wet floor (Class 2 baseline).
Dehumidifiers — baseline 1 AHAM pint/day per 100 cu ft of affected space (widely cited industry rule-of-thumb
for meaningful dehumidification); the class multiplier raises it for the evaporation load of wetter classes.
These are editable starting points, not the standard itself — always verify against the
current IICRC S500 and your company's procedures.