Drying Job Calculator

IICRC S500-based equipment sizing + daily drying log for water-damage restoration pros. Works fully offline — one file, no account, data stays on your device.

Job intake

Planning aid only. Sizing defaults are editable industry rules-of-thumb (see Settings for sources). Always verify against your IICRC S500 edition and adjust from daily psychrometric readings. Mold can begin within 24–48 hours in wet conditions — respond promptly.

Affected rooms

Dimensions in feet. Affected ft² = wet floor area (defaults to full floor — edit it down for partial rooms).
RoomDimensions (ft)Affected ft²Volume (cu ft) CarpetWet walls

Equipment sizing plan

RoomAir moversDehu share (AHAM pints/day)Notes
Air movers: one base unit per affected room + one per affected square feet ÷ class ratio (Class 2 default 60, inside the 50–70 range). Dehumidifiers: affected cubic feet × pints-per-cu-ft baseline × class multiplier → total AHAM pints/day, then ÷ your dehu capacity to get unit count. Defaults are editable in Settings. Verify on site — the S500 requires adjusting initial equipment from subsequent days' psychrometric readings.

Daily drying log

Log psychrometric + moisture readings per room per visit. The S500 requires the initial dehumidification plan to be adjusted from subsequent days' psychrometric readings — this log is that record. Balanced drying: keep dehumidification rate ≥ evaporation rate.
DateRoomTempRHSurface MCDry std ProgressEquipmentNotes

Settings & sizing ratios

Air-mover ratio: affected sq ft per mover (base 1 per room + affected ÷ ratio)

Dehumidifier class multiplier (× baseline pints)

Ratio sources (documented): Air movers — S500-derived industry rule-of-thumb: install one air mover in each affected room, then add one per 50–70 sq ft of wet floor (Class 2 baseline). Dehumidifiers — baseline 1 AHAM pint/day per 100 cu ft of affected space (widely cited industry rule-of-thumb for meaningful dehumidification); the class multiplier raises it for the evaporation load of wetter classes. These are editable starting points, not the standard itself — always verify against the current IICRC S500 and your company's procedures.

Data

Insurer-ready job summary